[1]Àî¿¡Òã,¿×ÉÍ,Âí»¢Éý,µÈ.×µÌå³ÉÐÎÊõÖйÇË®ÄàÉø©µÄÑо¿½øÕ¹[J].ÖÐÒ½Õý¹Ç,2019,31(09):41-45.
µã»÷¸´ÖÆ

×µÌå³ÉÐÎÊõÖйÇË®ÄàÉø©µÄÑо¿½øÕ¹()
·ÖÏíµ½£º

¡¶ÖÐÒ½Õý¹Ç¡·[ISSN:1001-6015/CN:41-1162/R]

¾í:
µÚ31¾í
ÆÚÊý:
2019Äê09ÆÚ
Ò³Âë:
41-45
À¸Ä¿:
×Û Êö
³ö°æÈÕÆÚ:
2019-09-20

ÎÄÕÂÐÅÏ¢/Info

×÷Õß:
Àî¿¡Òã1¿×ÉÍ2Âí»¢Éý1ÂíäìÜÛ3
(1.ºÓÄÏÊ¡ÂåÑôÕý¹ÇÒ½Ôº/ºÓÄÏÊ¡¹Ç¿ÆÒ½Ôº,ºÓÄÏ Ö£ÖÝ 450016; 2.ºÓÄÏÖÐÒ½Ò©´óѧ, ºÓÄÏ Ö£ÖÝ 450046; 3.ºþÄÏÖÐÒ½Ò©´óѧ,ºþÄÏ ³¤É³ 410208)
¹Ø¼ü´Ê:
×µÌå³ÉÐÎÊõ ÊÖÊõÖв¢·¢Ö¢ ¹ÇË®ÄàÉø© ×ÛÊö
ÕªÒª:
¹ÇË®ÄàÉø©ÊÇ×µÌå³ÉÐÎÊõ³£¼ûµÄ²¢·¢Ö¢,¿Éµ¼ÖÂÉñ¾­Ñ¹ÆȺͷÎ˨ÈûµÈÔÖÄÑÐÔºó¹û,ÈçºÎ¼õÉٺͱÜÃâ¹ÇË®ÄàÉø©һֱÊÇÑо¿Õß̽ÌÖµÄÈȵ㡣¹ÇË®ÄàÉø©Óë×µÌåµÄ½âÆÊÌص㡢¹ÇÕÛºó×µÌå¹ÇÖÊÆÆ»µ¡¢¹ÇÕÛºó×µÌåÄÚѹÁ¦Ôö¸ßµÈ¿Í¹ÛÒòËØÓйØ,ÓëÊõÕߵľ­Ñé¡¢ÊÖÊõ²Ù×÷ÊìÁ·³Ì¶ÈµÈÖ÷¹ÛÒòËØÒ²ÃÜÇÐÏà¹Ø¡£·ÀÖ¹¹ÇË®ÄàÉø©ҪÊìϤ׵Ìå½âÆʽṹ¡¢´¦Àí¹ÇÖÊÁÑ·ì¡¢¹æ·¶ÊÖÊõ²Ù×÷,¾¡Á¿¹æ±ÜÖ÷¹ÛÒòËصÄÓ°Ïì,²¢¼ÓÇ¿¶Ôм¼ÊõµÄ̽Ë÷¡£±¾ÎÄ´Ó¹ÇË®ÄàÉø©µÄΣº¦¡¢·ÖÐÍ¡¢Ô­ÒòºÍÔ¤·À²ßÂÔ¼¸¸ö·½Ãæ,¶Ô×µÌå³ÉÐÎÊõÖйÇË®ÄàÉø©µÄÑо¿½øÕ¹½øÐÐÁË×ÛÊö¡£

²Î¿¼ÎÄÏ×/References:

[1] CORCOS G,DBJAY J,MASTIER C,et al.Cement leakage in percutaneous vertebroplasty for spinal metastases[J].Spine(Phila Pa 1976),2014,39(5):e332-e338.
[2] PARK J H,KIM H S,KIM S W.Cement leakage into adjacent vertebral body following percutaneous vertebroplasty[J].Korean J Spine,2016,13(2):74-76.
[3] ÁõÑó,ÀîÃ÷»Ô,÷ºì¾ü.¾­Æ¤×µÌå³ÉÐÎÊõºó¹ÇË®ÄàÉø©µÄ»Ø¹ËÐÔ·ÖÎö¼°Ô¤·À²ßÂÔ[J].Öйú¹ÇÖÊÊèËÉÔÓÖ¾,2013,19(4):375-380.
[4] CHEN X,REN J,ZHANG J,et al.Impact of cement placement and leakage in osteoporotic vertebral compression fractures followed by percutaneous vertebroplasty[J].J Spinal Disord Tech,2016,29(7):e365-e370.
[5] Ëï·¢ÔË,³Âºì÷.×µÌå³ÉÐÎÊõÊõÖйÇË®ÄàÉø©ԭÒò·ÖÎö¼°·ÀÖβßÂÔ[J].°²»ÕÒ½Ò©,2013,17(7):1169-1170.
[6] ÿðþ ‰C ENTURK S,AKYOLDAS G,ÜNSAL Ü Ü,et al.Minimally invasive translaminar endoscopic approach to percutaneous vertebroplasty cement leakage:technical note[J].World Neurosurg,2018,117:15-19.
[7] ZHAO Y T,LIU T J,ZHENG Y H,et al.Successful percutaneous retrieval of a large pulmonary cement embolus caused by cement leakage during percutaneous vertebroplasty case report and literature review[J].Spine(Phila Pa 1976),2014,39(26):e1616-e1621.
[8] ËïÆô²Å,ÈãÑ¡Á¼,ËΰØɼ,µÈ.¾­Æ¤×µÌåºó͹³ÉÐÎÊõ¹ÇË®ÄàÉø©µÄÖÐÆÚËæ·Ã¼°Ó¦¶Ô²ßÂÔ[J].Öйú¹ÇÉË,2017,30(9):810-816.
[9] YEOM J S,KIM W J,CHOY W S,et al.Leakage of cement in percutaneous transpedicular vertebroplasty for painful osteoporotic compression fractures[J].J Bone Joint Surg Br,2003,85(1):83-89.
[10] DING J,ZHANG Q,ZHU J,et al.Risk factors for predicting cement leakage following percutaneous vertebroplasty for osteoporotic vertebral compression fractures[J].Eur Spine J,2016,25(11):3411-3417.
[11] WANG C,ZHAO F.Re:identification of risk factors for the occurrence of cement leakage during percutaneous vertebroplasty for painful osteoporotic or malignant vertebral fracture[J].Spine(Phila Pa 1976),2015,40(13):1055.
[12] ÀîÖÇ,Öܺ£ÁÖ,Î⺣»Ô,µÈ.¹ÇÖÊÊèËÉÐÔÐØÑü×µ¹ÇÕÛ¾­Æ¤×µÌåºó͹³ÉÐÎÊõºó²¢·¢¹ÇË®ÄàÉø©µÄÁÙ´²¹Û²ì¼°·ÖÎö[J].¹ú¼Ê¹Ç¿ÆѧÔÓÖ¾,2014,35(6):400-402.
[13] HULME P A,KREBS J,FERGUSON S J,et al.Vertebroplasty and kyphoplasty:a systematic review of 69 clinical studies[J].Spine(Phila Pa 1976),2006,31(17):1983-2001.
[14] LIU T,LI Z,SU Q,et al.Cement leakage in osteoporotic vertebral compression fractures with cortical defect using high-viscosity bone cement during unilateral percutaneous kyphoplasty surgery[J].Medicine(Baltimore),2017,96(25):e7216.
[15] ÁºµÂ,Ò¶ÁÖÇ¿,½­Ïþ±ø,µÈ.¹ÇË®Äà-×µÌåÌå»ý±È¼°×µÌå¹Ç±ÚÁÑ¿ÚÓ뾭Ƥ׵Ìå³ÉÐÎÊõ¹ÇË®ÄàÉø©µÄÏà¹ØÐÔ·ÖÎö[J].ÖйúÐÞ¸´Öؽ¨Íâ¿ÆÔÓÖ¾,2014,28(11):1358-1363.
[16] Ò¦ÓñÁú,³Ì×ÓÔÏ,ÕÅÀÚÀÚ,µÈ.¾­Æ¤×µÌå³ÉÐÎÊõºó×µ¹ÜÄÚ¹ÇË®ÄàÉø©µÄ»Ø¹ËÐÔÑо¿[J].Öйú½ÃÐÎÍâ¿ÆÔÓÖ¾,2015,23(24):2209-2213.
[17] ¿µÐ¡Ñà,Àî½à,ÍõÐÇ,µÈ.ÐØ×µ×µ»ù¾²Âö¿×µÄCTÓ°Ïñѧ¹Û²â[J].ÖйúÁÙ´²½âÆÊѧÔÓÖ¾,2015,33(6):641-645.
[18] ÍõÓÀ½­,ÍõÇå,Ò¦çù.PKPÖÎÁƹÇÖÊÊèËÉÐÔ±¬ÁѹÇÕÛÁÆЧ¼°¹ÇË®ÄàÉø©;¾¶µÄ̽ÌÖ[J].ÖØÇìҽѧ,2015,44(11):1457-1459.
[19] WANG C,FAN S,LIU J,et al.Basivertebral foramen could be connected with intravertebral cleft:a potential risk factor of cement leakage in percutaneous kyphoplasty[J].Spine J,2014,14(8):1551-1558.
[20] ÖÓÔ¶Ãù,¸¶Ë©»¢,ÕżÒÁ¢,µÈ.¾­Æ¤´©´Ì×µÌå³ÉÐÎÊõÖйÇË®ÄàÉø©µÄÔ­Òò¼°Ô¤·À[J].Öйú½ÃÐÎÍâ¿ÆÔÓÖ¾,2014,22(4):294-298.
[21] Ê·ÌÚ,ËÕÏéÕý,ÖÜÁÁ,µÈ.¾­Æ¤×µÌå³ÉÐÎÊõ¹ÇË®ÄàÉø©Ïà¹ØÒòËØ·ÖÎö[J].½â·Å¾üҽѧԺѧ±¨,2014,35(11):1093-1096.
[22] ÌÆÖ¾ºê,×Þ¹úÒ«,Фӱ,µÈ.ÐØÑü¶Î×µÌåÄÚѪ¹Ü·Ö²¼Ó밲ȫÇøÄÚ´©´Ì¼õÉÙ¹ÇË®ÄàµÄÉø©[J].Öйú×éÖ¯¹¤³ÌÑо¿,2013,17(3):387-391.
[23] INOUE M,SAKANE M,TAGUCHI T.Fabrication of reactive poly(vinyl alcohol)membranes for prevention of bone cement leakage[J].J Biomed Mater Res B Appl Biomater,2014,102(8):1786-1791.
[24] ÐìÁÖ·É,ºúÕìÃ÷,½­Î¬,µÈ.Ã÷½ºº£ÃàԤעÉäÔÚ×µÌå³ÉÐÎÊõÖÐÔ¤·À¹ÇË®ÄàÉø©µÄÌåÍâÑо¿[J].ÖØÇìÒ½¿Æ´óѧѧ±¨,2015,40(2):207-211.
[25] ÑîÖÇÏÍ,ÅíСÖÒ,׿ÏéÁú,µÈ.×µÌå³ÉÐÎÊõÖÐ×¢ÉäÃ÷½ºº£ÃàÔ¤·À¹ÇË®ÄàÉø©µÄÁÙ´²¹Û²ì[J].Öйú¹ÇÓë¹Ø½ÚËðÉËÔÓÖ¾,2014,29(5):479-480.
[26] ³ÂÖÇÄÜ,ËïÕýÓÑ,Ò¶¿¡²Ä,µÈ.Ã÷½ºº£ÃàµÄʹÓöÔ×µÌåºó͹³ÉÐÎÊõÖйÇË®ÄàÉø©µÄÓ°Ïì[J].Öйú¹ÇÓë¹Ø½ÚËðÉËÔÓÖ¾,2015,30(11):1145-1148.
[27] OH J S,DOH J W,SHIM J J,et al.The effectiveness of gelfoam technique before percutaneous vertebroplasy:is it helpful for prevention of cement leakage?a prospective randomized control study[J].Korean J Spine,2016,13(2):63-66.
[28] ÐìÔ¾¸ù,ÂÞÔ¶Ã÷.¾­Æ¤×µÌåºó͹³ÉÐÎÊõÖзֲ½ÍÆ×¢¹ÇË®ÄàÖÎÁÆ×µÌåºó±ÚÆÆËðµÄ¹ÇÖÊÊèËÉÐÔ×µÌå¹ÇÕÛ[J].ÁÙ´²¹Ç¿ÆÔÓÖ¾,2013,16(6):624-626.
[29] À»ª,Áõѵΰ,ÅíÏæÌÎ,µÈ.¹ÇÌî³äÍø´ü¹à×¢¹ÇË®ÄàÐÞ¸´×µÌåѹËõ¹ÇÕÛ:¿É½µµÍ¹ÇË®Äà×µÌåÍâÉø©ÂÊ[J].Öйú×éÖ¯¹¤³ÌÑо¿,2015,19(3):358-363.
[30] ¶­¸Õ,ÀÖ¾ü,ÖÜ»Ô,µÈ.×µÌåÄÚ²¿Ç¿»¯ÊõÖÎÁƹÇÖÊÊèËÉÐÔ×µÌåѹËõ¹ÇÕÛ²¢·¢¹ÇË®ÄàÉø©µÄÁÙ´²¹Û²ì[J].Öйú¹ÇÉË,2014,27(06):504-507..
[31] BOKOV A,MLYAVYKH S,ALEYNIK A,et al.The potential impact of venobasillar system morphology and applied technique on epidural cement leakage with percutaneous vertebroplasty[J].Pain Physician,2016,19(6):357-362.
[32] Áõ¼ÓÔª,ÀîÒµ³É,ÁõÊØÕý,µÈ.µ¥±ß°Ðµã´©´Ì·ÖÆÚ¹à×¢¹ÇË®ÄྭƤ׵Ìå³ÉÐÎÊõÖÎÁÆ°é×µÌåÄÚÁÑ϶Õ÷Ö®¹ÇÖÊÊèËÉÐÔÐØÑü×µ¹ÇÕÛ[J].΢´´Ò½Ñ§,2014,9(1):57-60.
[33] HOPPE S,WANGLER S,AGHAYEV E,et al.Reduction of cement leakage by sequential PMMA application in a vertebroplasty model[J].Eur Spine J,2016,25(11):3450-3455.
[34] SUN H B,JING X S,LIU Y Z,et al.The optimal volume fraction in percutaneous vertebroplasty evaluated by pain relief,cement dispersion,and cement leakage:a prospective cohort study of 130 patients with painful osteoporotic vertebral compression fracture in the thoracolumbar vertebra[J].World Neurosurg,2018,114:e677-e688.
[35] FU Z,HU X,WU Y,et al.Is there a dose-response relationship of cement volume with cement leakage and pain relief after vertebroplasty?[J].Dose Response,2016,14(4):1559325816682867.
[36] ZHU S Y,ZHONG Z M,WU Q,et al.Risk factors for bone cement leakage in percutaneous vertebroplasty:a retrospective study of four hundred and eighty five patients[J].Int Orthop,2016,40(6):1205-1210.
[37] Àî×ÔÇ¿,¶Å¿Æΰ,¶ÅÏÄÃú,µÈ.×µÌå³ÉÐÎÊõÓë×µÌåºó͹³ÉÐÎÊõÖÎÁƹÇÖÊÊèËÉÐÔ×µÌåѹËõÐÔ¹ÇÕÛ·¢Éú¹ÇË®ÄàÉø©µÄÏà¹ØÁÙ´²ÆÀ¼Û[J].½â·Å¾üÒ½Ò©ÔÓÖ¾,2016,28(5):54-58.
[38] WANG H,SRIBASTAV S S,YE F,et al.Comparison of percutaneous vertebroplasty and balloon kyphoplasty for the treatment of single level vertebral compression fractures:a meta-analysis of the literature[J].Pain Physician,2015,18(3):209-222.
[39] Îâºè,Ô¬Ô´,ÁõÀñ½ð,µÈ.µ¥²à¾­Æ¤×µÌå³ÉÐÎÐÞ¸´¹ÇÖÊÊèËÉÐÔ×µÌåѹËõÐÔ¹ÇÕÛ:¹ÇË®ÄàÉø©ÉÙÀûÓÚ»Ö¸´[J].Öйú×éÖ¯¹¤³ÌÑо¿,2015,19(31):4960-4966.
[40] PALM H G,RIESNER H J,LANG P,et al.Diagnostic accuracy of fluoroscopy,radiography,and computed tomography in detecting cement leakage in kyphoplasty[J].J Neurol Surg A Cent Eur Neurosurg,2018,79(6):502-510.
[41] ÀîËÉ»ª,Ñî¿­,ÉêÓñÀ¼,µÈ.Innova3D¼¼ÊõÖ¸µ¼¾­Æ¤×µÌå³ÉÐδ©´Ì·¾¶:½µµÍ¹ÇË®ÄàÉø͸·¢ÉúÂÊ[J].Öйú×éÖ¯¹¤³ÌÑо¿,2015,19(16):2473-2478.
[42] ÕÅ־ǿ,Ñ¶«,·ëÐÂÃñ,µÈ.¸ÄÁ¼¹ÇË®ÄàÍÆ×¢Ì×¹ÜÖÎÁƹÇÖÊÊèËÉ×µÌåѹËõÐÔ¹ÇÕۿɼõÉÙ¹ÇË®ÄàÉø©[J].Öйú×éÖ¯¹¤³ÌÑо¿,2018,22(2):165-170.
[43] LI J,LI T,MA Q,et al.Using side-opening injection cannulas to prevent cement leakage in percutaneous vertebroplasty for osteoporotic vertebral compression fractures,does it really work?[J].J Orthop Sci,2017,22(5):811-815.
[44] ÕÔʤ¾ü,ÕÔÀö,½ð±¦³Ç,µÈ.²à¿ª¿Ú¹ÇË®ÄàÍÆ×¢Æ÷½áºÏ·Ö½×¶Î×¢Éä¼¼ÊõÖÎÁÆÀÏÄêÐØÑü¶Î¹ÇÖÊÊèËÉÐÔѹËõ¹ÇÕÛÁÆЧ·ÖÎö[J].´óÁ¬Ò½¿Æ´óѧѧ±¨,2018,40(5):418-423.
[45] JIN P,LIU X,LI M,et al.Clinical experience using a remote control injection system in vertebroplasty:feasibility,safety,and cement leakage of osteoporotic and malignant compression fractures[J].J Spinal Disord Tech,2017,30(3):e305-e309.
[46] ARABMOTLAGH M,RICKERT M,LUKAS A,et al.Small cavity creation in the vertebral body reduces the rate of cement leakage during vertebroplasty[J].J Orthop Res,2017,35(1):154-159.
[47] HOPPE S,ELFIKY T,KEEL M J,et al.Lavage prior to vertebral augmentation reduces the risk for cement leakage[J].Eur Spine J,2016,25(11):3463-3469.

ÏàËÆÎÄÏ×/References:

[1]ËÎʿѧ,³ÂÓï,Ö£ÁÁ,µÈ.å¾Êà×µÂݶ¤Äڹ̶¨ÈÚºÏÊõÖÎÁÆå¾Êà׵ʧÎȵIJ¢·¢Ö¢·ÖÎö[J].ÖÐÒ½Õý¹Ç,2020,32(04):68.
[2]¸ßì¾,ÎâÞȽ­,պΪ,µÈ.бÍâ²àÑü×µ¼äÈÚºÏÊõ²¢·¢Ö¢µÄÑо¿½øÕ¹[J].ÖÐÒ½Õý¹Ç,2020,32(11):29.
[3]Äßǰΰ,´÷ÓíÈó,½ðÁ¢À¥,µÈ.õ׹ؽÚ3.5mmÈ«ÂÝÎÆ¿ÕÐÄÎÞÍ·¼ÓѹÂݶ¤È¡³öÀ§ÄÑÔ­Òò·ÖÎö[J].ÖÐÒ½Õý¹Ç,2021,33(02):17.
¡¡NI Qianwei,DAI Yurun,JIN Likun,et al.Cause analysis of difficulty in removal of 3.5-mm diameter full-thread hollow headless compression screws used for treatment of ankle fractures[J].The Journal of Traditional Chinese Orthopedics and Traumatology,2021,33(09):17.
[4]Ðí½õ³¬,±«½£º½,¸ßÎÄ˶,µÈ.µ¥²àÈë·˫²à¼õѹÊõÖÎÁÆÍËÐÐÐÔÑü×µ×µ¹ÜÏÁÕ­Ö¢Ïà¹Ø²¢·¢Ö¢µÄÑо¿½øÕ¹[J].ÖÐÒ½Õý¹Ç,2021,33(03):44.
¡¡XU Jinchao,BAO Jianhang,GAO Wenshuo,et al.Advancement of research on complications of unilateral laminotomy for bilateral decompression for treatment of degenerative lumbar spinal stenosis[J].The Journal of Traditional Chinese Orthopedics and Traumatology,2021,33(09):44.
[5]Æá¹ú¶°,ÎÄ»¯,Æáΰ,µÈ.ÊÖÊõÓë·ÇÊÖÊõÖÎÁÆëŹǸɹÇÕÛ°²È«ÐÔµÄMeta·ÖÎö[J].ÖÐÒ½Õý¹Ç,2021,33(08):33.
¡¡QI Guodong,WEN Hua,QI Wei,et al.Comparison of the safety of surgical treatment versus nonsurgical treatment for humeral shaft fractures:a meta-analysis[J].The Journal of Traditional Chinese Orthopedics and Traumatology,2021,33(09):33.
[6]Ñ¾§,ÍõÍþ,ºÎ³Ð½¨,µÈ.¹ÇÖÊÊèËÉÐÔ×µÌåѹËõ¹ÇÕÛ¾­Æ¤×µÌå³ÉÐÎÊõÖйÇË®Äà×µ¼äÅÌÉø©¶ÔÊÖÊõÁÆЧµÄÓ°Ïì¡­[J].ÖÐÒ½Õý¹Ç,2022,34(01):15.
¡¡YANG Jingjing,WANG Wei,HE Chengjian,et al.Effects of intradiscal bone cement leakage on the clinical outcome of percutaneous vertebroplasty for treatment of osteoporotic vertebral compression fracture[J].The Journal of Traditional Chinese Orthopedics and Traumatology,2022,34(09):15.
[7]Â޼ѼÑ,Æ»ª,Ñîì³,µÈ.×µÌå³ÉÐÎÊõºóз¢×µÌåѹËõÐÔ¹ÇÕÛµÄÓ°ÏìÒòËØ[J].ÖÐÒ½Õý¹Ç,2022,34(06):42.
[8]ÁõÎÀÒå,Û³ÎÀƽ,ÕÅάƽ.¼¹ÖùÊÖÊõ²¢·¢Ó²¼¹Ä¤ËºÁѺÍÄÔ¼¹ÒºÂ©µÄÑо¿½øÕ¹[J].ÖÐÒ½Õý¹Ç,2022,34(06):47.
[9]ÁõÈñ,¹¨µÂ·É,°àÕýÌÎ,µÈ.¾­Æ¤×µÌå³ÉÐÎÊõÖÎÁƹÇÖÊÊèËÉÐÔ×µÌåѹËõ¹ÇÕÛÊõÖйÇË®ÄàÉø©µÄΣÏÕÒòËØ·ÖÎö[J].ÖÐÒ½Õý¹Ç,2022,34(11):14.
¡¡LIU Rui,GONG Defei,BAN Zhengtao,et al.Risk factors for bone cement leakage during percutaneous vertebroplasty treatment of osteoporotic vertebral compression fractures[J].The Journal of Traditional Chinese Orthopedics and Traumatology,2022,34(09):14.
[10]ÕÔÁì·å,ÒõСÁú.¾­Æ¤×µÌåÇ¿»¯ÊõºóÑü±³²¿ÌÛÍ´Ó°ÏìÒòËصÄÑо¿½øÕ¹[J].ÖÐÒ½Õý¹Ç,2023,35(07):46.

±¸×¢/Memo

±¸×¢/Memo:
(ÊÕ¸åÈÕÆÚ:2019-04-18 ±¾Îı༭:ÑîÑÅ)
¸üÐÂÈÕÆÚ/Last Update: 2019-09-15